How to Read a Peptide COA: HPLC, Mass Spec, Endotoxin
[Guide · Lab and testing]

Lab testing and COAs: reading the data

6 min read · Also in the Dose Track app under Learn · Updated

Short answer: A Certificate of Analysis (COA) is a lab report for one batch. HPLC tells you how pure the sample is; mass spectrometry tells you what it is. You need both, from a named independent lab, with a lot number that matches your vial. Bloodwork then tells you how your body responds.

What a COA is

A COA reports tests on a specific lot. It is the only outside check that the powder matches the label. A purity claim on a product page with no report behind it tells you nothing. A report from the seller's own lab counts for less than one from an independent lab.

HPLC: how pure

High-performance liquid chromatography pushes the sample through a packed column. Different compounds come out at different times and show up as peaks on a chart (the chromatogram).

  • Purity = the area of the main peak ÷ the area of all peaks.
  • The main peak should dominate and come out at the expected time.
  • Small extra peaks are other things: breakdown products, shortened chains or leftovers from making it.
  • Look at the chart itself, not only the number. Big side peaks with a high headline number do not add up.

HPLC does not tell you what the main peak is.

Mass spectrometry: what it is

Mass spectrometry measures the mass of the molecule. Every peptide has a known expected mass: BPC-157 is 1419.5 g/mol and semaglutide about 4114 g/mol, per PubChem. A match confirms identity; a mismatch means the wrong compound, a labeling error, or a failed synthesis.

HPLC alone could show 99% purity of the wrong molecule. Mass spec alone says nothing about impurities. You need both. A combined LC-MS report covers both at once.

Other tests

  • Endotoxin (LAL test): finds bacterial toxins that cause fever and inflammation. Important for anything injected. Acceptable limits depend on the dose and route.
  • Sterility: checks for live bacteria and fungi.
  • Residual solvents: chemicals such as acetonitrile and DMF used in making peptides. The ICH Q3C guideline sets limits for drugs. TFA left over from purification is also common.
  • Heavy metals: more relevant for plant-based supplements than for made peptides.

Green flags and red flags

Scanning a COA
Green flagRed flag
Named independent lab you can find"In-house" or no lab named
Lot number matches your vialNo lot number, or it does not match
Recent test date for this lotNo date, or very old
Exact purity with the method"High purity" or ">95%" only
HPLC and mass spec, with chartsOnly one of the two
Clean, readable report from the labBlurry, edited-looking PDF; same report reused across lots

Pair it with bloodwork

A COA checks the product. Bloodwork checks your response.

  • Growth hormone peptides: IGF-1 is the main marker. If the COA looks clean but IGF-1 does not move after a few weeks at a steady dose, the cause may be the dose, storage, or a vial that does not match its report.
  • GLP-1 drugs: fasting glucose, HbA1c, lipids and liver enzymes.
  • Repair peptides: blood tests say less; inflammation markers like hs-CRP are sometimes followed.

Get a baseline before starting and recheck with your clinician. Trends say more than one result. You can keep results in Dose Track; see upload labs and lab targets.

Key points

  • HPLC shows purity; mass spectrometry shows identity. You need both.
  • The lab should be named and independent, and the lot number should match your vial.
  • For injected products, look for endotoxin testing.
  • Bloodwork shows whether the product is doing what it should in you.

See also: Upload labs in Dose Track · Lab targets

This guide is general education, not medical advice. Follow your medicine's label and your prescriber.

Compounds in this guide

Frequently asked questions

What is the difference between HPLC and mass spec?+
HPLC measures how pure a sample is. Mass spectrometry measures the molecule's mass to confirm what it is. A trustworthy report has both.
What is the molecular weight of BPC-157?+
About 1419.5 g/mol, per PubChem. A mass spec result should match it.
How recent should a COA be?+
It should be for the exact lot you received. A report reused across lots or with no date is a warning sign.